Rooftop units
Air-to-air rooftop units, cooling only
Reversible air cooled fully configurable high efficiency Rooftop units 50,8-240 kW
Series
WRX-T 0162 - 0804

Autonomous reversible air-to-air Rooftop unit, for the thermo-hygrometric treatment, filtration and air renovation, in medium-large surface and
volume ambient, such as supermarkets, shopping or exhibition centres. Hermetic rotary scroll compressors with R410A refrigerant; double
refrigerant circuit fitted with Electronic Expansion Valves; EC plug fans are standard on these units. The structure is specific for outdoor installation, with base and supporting structure made of hot galvanized sheet metal profiles of adequate thickness. The vertical structure and outer panelling are also painted with polyester powders RAL 7035. The air treatment section is insulated internally with a double layer high tech material. The insulation is fixed with specific adhesives to the sheet metal together with mechanical fastenings that guarantee maximum hold over time.

According to the selected version, the unit allows for the management of free cooling, with supply and return fans with motorized dampers for
return, expulsion and fresh air.

The unit can be supplied with 4 types of heat recovery: thermodynamic recovery, Refrigerant Booster (an additional refrigerant coil placed on
exhaust air flow), air-to air Plate or Rotary, to recover the energy from the exhaust air, increasing unit capacity and the global efficiency.

Controls

AIR3000TE
The AIR3000 TE controller offers advanced functions and algorithms. It is made up by two control boards, dedicated to the air side and the refrigerant side respectively. The keypad features functional controls and a complete LCD display that allows for unit monitoring and intervention by means of a multilevel menu with a selectable user language.

Temperature control is based on PID logic according to the supply temperature set point. It is possible to have set point compensation according to outdoor temperature, both in winter and summer. The operating mode of the unit, cooling/heating/free cooling, is managed automatically. Constant air volume ventilation control is standard: as pressure drop varies, the fans change speed to maintain flow-rate at the design value for the system, according to how dirty the filters are. As an option the air flow can be managed according to a CO2 or CO2 + VOC probe.

The controller can also integrate and automatically manage different optional devices: pre-treatment coil, electric heater, gas-fired heating module, humidifier. Unloading modulation function is available for part-load refrigerant circuit operation in critical conditions.

Supervision is available with different options, using proprietary devices or by integration with third party systems using ModBus, BACnet, BACnet-over-IP and Echelon LonWorks protocols.

Compatible with remote keypad (management of up to 8 units).

The timer can be used to create an operating profile with up to 4 typical days and 10 different time bands.

Features
Models

Characteristics

CONFIGURATIONS

AR          Air recirculation function

MF         Mixing and Free cooling function

AX         Mixing and Free cooling function with Exhaust air Axial fan

HR-F     Heat Recovery Free: air extractor fan(s), free cooling function and thermodynamic heat recovery from exhaust air flow

HR-B     Heat Recovery Refrigerant Booster function: air extractor fan(s), free cooling function and heat recovery from exhaust air flow thanks to Refrigerant Booster coil

HR-P    Heat Recovery Plate function: air extractor fan(s), free cooling function and heat recovery from exhaust air flow thanks to Plate heat
Exchanger.

HR-E     Heat Recovery Enthalpy function: air extractor fan(s), free cooling function and heat recovery from exhaust air flow thanks to Rotary
Enthalpic Wheel.

ВЫСОКАЯ НАДЕЖНОСТЬ

Широкий рабочий диапазон, двойной контур хладагента и точный дизайн компонентов обеспечивают оптимальную производительность и комфорт при непрерывной и постоянной работе также при тяжелых термогигрометрических условиях. 

УНИВЕРСАЛЬНОСТЬ

Устройство доступно с возможностью выбора различных направлений подачи и возврата воздуха. 

ГИБКОСТЬ

Различные возможности для камер обработки воздуха; от полной рециркуляции только до подмеса свежего воздуха и экстракции из окружающей среды с рекуперацией тепла. Каждая прочая конфигурация может быть дополнительно настроена благодаря широкому набору аксессуаров. 

РЕГЕНЕРАЦИЯ ТЕПЛА ОТ ВЫХОДЯЩЕГО ВОЗДУШНОГО ПОТОКА

Блоки могут быть оснащены 4 различными системами рекуперации тепла для удовлетворения широкого спектра потребностей. 

ПЛЮС ВЕНТИЛЯТОРЫ ВЕНТИЛЯЦИИ

Вентиляторы с питанием и обратной связью обеспечивают сочетание высокой эффективности вентиляционной секции с простой и быстрой установкой агрегата, как в электрическом, так и в аэродинамическом подсоединении. 

Аксессуары

  • Теплообменник энтальпии для естественного охлаждения
  • Настройка удаленного подключения к картам протокола ModBus / Echelon
  • Регулирование расхода воздуха с помощью датчиков CO2 или CO2 + VOC
  • Интеграция или замена ресурсов тепла: теплообменник нагрева горячей воды, электронагреватели, модуль газового отопления