Air Cooled Heat Pump Chillers
PYXIS HP
Series
U... 42÷222KW

MAIN FEATURES:

  • Air-to-water heat pump.
  • Wide range of aggregates including 32 models.
  • Average step of 10 kW.
  • EER up to 3.10.
  • COP up to 3.26.
  • ESEER up to 4.58.
  • Scroll compressors.
  • Chargeable refrigerant - R410A.
  • Single, double refrigerant circuit
  • Plate heat exchanger.
  • Axial AC fans.
  • Single refrigeration circuit.
  • Suitable for outdoor installation.
Features

WORKING LIMITS IN COOLING MODE:

  • Chilled water outlet temperature: -12÷20°C
  • Ambient temperature: -10÷45°C

 

WORKING LIMITS IN HEATING MODE:

  • Hot water outlet temperature: 30÷60°C
  • Ambient temperature: -12÷30°C

 

 ADVANTAGES:

  • IDEA® dynamic defrost monitoring system.
  • Two scroll compressors for each refrigeration circuit.
  • One or two refrigeration circuits.
  • Seaprarted air circuits.
  • Electronic expansion valve.
  • High rates of EER, COP and ESEER.
  • Heat exchangers with water-repelling/waterproof coating.
  • Noise-supressing super-noise-suppressing kits.
  • Pumping groups with low, medium and high pressure.
  • Easy maintenance.
  • Eurovent certification.

 

POWER SUPPLY U1 - U2 - U3L - U4L: 400/3/50 + N

POWER SUPPLY U3 - U4: 400/3/50

 

 COMPONENTS:

  • FRAMEWORK: steel with protective epoxy coating; color: RAL 9002.
  • COMPRESSORS: scroll compressors; 2-pole 3-phase electric motor with direct on line starting; phases control relay; crankcase heater; thermal protection of the motor via temperature sensors; rubber supports.
  • REFRIGERATING CIRCUIT: reversing valve for refrigerant circuit inversion; sight glass; liquid receiver; service valves on suction line and gas discharge; pressure sensors with the function of indication, monitoring and protection against pressure drops of the refrigerant; oil purification and regeneration system; IDEA® dynamic defrost monitoring system.
  • CONDENSER: copper tubes with aluminum fins, which increase the heat transfer of the system and reduce the pressure drop; Characterized by: maximum performance; minimum refrigerant charge; reduced air consumption; frame made of galvanized steel.
  • ELECTRICAL PANEL: main switch with safety lock; fuses for compressors; switches for fans of magneto-thermal type; contactors for the compressor; transformer for the circuit and power supply of the microprocessor; panel with machine controls.
  • CONTROL SYSTEM: MP.COM microprocessor control with graphical display; real time clock; flash memory; components hour-meter; a password-protected menu; LAN connection.