Heat pumps
Air to water reversible heat pumps
Split system heat pumps for indoor installation 20 - 400 kW
Series
MANTA EVO A HP

MAIN FEATURES

  • Split system heat pump liquid chiller.
  • 22 models, 2 versions available, for a wide selection opportunity.
  • Average step of 20kW.
  • EER up to 3,02.
  • COP up to 3,18.
  • Scroll compressors.
  • R410A Refrigerant charge.
  • Plate type heat exchangers.
  • Suitable for indoor installation.
  • Split system.

MAIN BENEFITS

  • New frame, more compact, suitable to walks in through a standard door;
  • Hydraulic connections on the top side of the machine;
  • Reduction of service spare around the machine;
  • New control software, developed by RC Group, with an advanced control logic;
  • Increased cooling density, up to 180kW per m2 ;
  • Increased heating density, up to 205kW per m2 ;
  • Total front access for the routine maintenance;
  • Up to two compressors for each refrigerant circuit to reach a high efficiency.
  • Units with single or double refrigerant circuits.
  • Low sound level guaranteed by the cabinet structure;
  • Availability of plant side pumping groups.
  • Availability of partial heat recovery system.
  • Easily of maintenance.
  • Up to A+ Class. ErP 2015.

INDOOR INSTALLATION  

Machines designed for indoor installation.

REMOTE EXCHANGER

The units are designed to be matched with remote exchanger with axial fans (TEAM MATE HP series) or plug-fan (TEAM MATE HP PF series).

REDUCED NOISE EMISSION

The machines are characterized by a low sound level guaranteed by the containing structure.

NEW FRAME, MORE COMPACT to walks in through a standard door.

HYDRAULIC CONNECTION ON THE TOP SIDE OF THE MACHINE

WORKING LIMITS IN COOLING MODE

Evaporator chilled water outlet temperature: -12÷20°C Ambient temperature: -10÷45°C

WORKING LIMITS IN HEATING MODE

Condenser hot water outlet temperature: 30÷60°C Ambient temperature: -12÷30°C

Features
Models

MAIN COMPONENTS

FRAMEWORK

  • Base in aluminium extrusion, painted with epoxy powders. Colour RAL 9005;
  • Supporting feet in galvanized steel sheet with holes for floor fixing or rubber shock absorbers installation;
  • Inner frame and upper frame in aluminium profile, painted with epoxy powders. The inner frame is provided with seals for the panels. Colour RAL 9005;
  •  Panels in galvanized steel sheet with protective surfaces treatment in compliance with UNI ISO 9227/ASTMB117 and ISO 7253, and painted with epoxy powders. Colour RAL 7016 hammered;
  •  Removable frontal panels for a total front access for routine maintenance;
  •  Removable side panels with grilles for interior ventilation;
  •  Compartment for electrical panel on unit front for direct access to control and regulation devices;
  •  Hydraulic and refrigerant connections on the machine top cover.

COMPRESSORS

  •  Orbiting spiral (SCROLL) hermetic compressors with spiral profile optimized for R410A refrigerant;
  •  ON / OFF capacity control (0 / 100% each compressor);
  •  2-pole 3-phase electric motor with direct on line starting;
  •  Crankcase heater;
  •  Electric motor thermal protection via internal winding temperature sensors;
  •  Equalization system of the lubricant oil for units equipped with 2 or 3 compressors operating on the same refrigerating circuit;
  •  Rubber supports.

PLANT SIDE HEAT EXCHANGER

  •  AISI 316 stainless steel plates type, vacuum brazed using copper as brazing material. Hydraulic and refrigerant connections in AISI 316 stainless steel:

- With single hydraulic circuit for all machines;
- With single refrigerant circuit for S version machines – size M1, M2, M3;
- With double refrigerant circuit for D version machines – size M4

  •  Polyurethane insulation foam with closed cell;
  •  Temperature sensors on water inlet and outlet;
  •  Factory assembled differential water pressure switch for water flow control;
  •  Hydraulic piping insulated with closed cell elastomeric foam;
  •  Hydraulic connections on the machine top cover.

REFRIGERANT CIRCUIT

Components for each refrigerant circuit:

  •  Reversing valve for refrigeration cycle inversion
  •  Thermostatic expansion valve;
  •  Electronic expansion valve for models 236 P2 S – 284 P4 D – 328 P4 D -372 P4 D – 422 – P4 D - 472 P4 D P4 D;
  •  Sight glass;
  •  Electromagnetic valve on liquid line. The valve is not installed on models 236 P2 S - 280 P3 S – 328 P4 D - 372 P4 D – 422 – P4 D - 472 P4 D;
  •  Filter dryer on liquid line;
  •  Service valve on liquid line upstream the filter dryer. The valve is present only with exchangeable cartridge filter;
  •  Safety valves on high and low pressure side;
  •  Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure;
  •  High pressure safety switch with manual reset;
  •  Liquid receiver with safety valve and service valve;
  •  Liquid separator with safety valve on compressor suction side;
  •  Valves on gas delivery and liquid return for coupling to remote air cooled condenser.
  •  Refrigerant circuit with copper tubing with insulation of the suction line;
  •  Plastic capillary hoses for pressure sensors connection;
  •  R410A refrigerant charge.

ELECTRICAL PANEL

In accordance with EN60204-1 norms, suitable for indoor installation, complete with:

  •  Main switch with door lock safety on frontal panel;
  •  Magnetothermic switches or fuses for each compressor;
  •  Contactors for each compressor motor;
  •  Transformer for auxiliary circuit and microprocessor supply;
  •  Machine operating mode selector “Loc – Off - Remote”:

- Loc position: Machine is active;
- Off position: Machine is deactivated;
- Remote position: The machine is remotely controlled with a command by the Customer. Electric connections in the terminal.

  •  Machine operating mode selector “Summer – Winter - Remote”:

- Summer position: Summer working mode with chilled water production.
- Winter position: Winter working mode with hot water production.
- Remote position: The machine is remotely controlled with a command by the Customer. Electric connections in the terminal.

  •  Terminals:

OUTLETS

- Voltage free deviating contact for General Alarm 1.
- Voltage free deviating contact for General Alarm 2 – only for units with single refrigerant circuit.

INLETS

- External enabling (from timer, ecc. At Customer care);
- Remote control (from operating mode selector. At Customer care);
- Emergency unit stop with signalling on display (external alarm. At Customer care).;

  •  Panel with machine controls;
  •  Power supply: 400V / 3Ph / 50Hz.

CONTROL SYSTEM

Microprocessor control system with graphic display for control and monitor of operating and alarms status. The system includes:

  •  Built-in clock for alarms date and time displaying and storing;
  •  Built-in memory for the storing of the intervened events (up to 100 events recorded);
  •  Predisposition for connectivity board housing ( RCcom MBUS/JBUS, LON, BACnet for Ethernet (SNMP- TCP/IP), BACnet for MS/TP). The electronic cards are optional accessories;
  •  Main components hour-meter;
  •  Non-volatile “Flash” memory for data storage in case of power supply faulty;
  •  Analogue set point compensation (0÷10 Vdc) according to an external analogue signal at Customer care;
  •  Menu with protection password;
  •  LAN connection (max 15 units).

TO BE MATCHED WITH REMOTE EXHAUSTION HEAT EXCHANGERS

  •  MANTA EVO A HP series is designed to be matched with remote air/gas exhaustion heat exchangers with axial fans (TEAM MATE HP series) or plugfan (TEAM MATE HP PF series).