Multifunctional Systems
MULTIPLO SCREW
Series
190÷1153KW

MAIN FEATURES:

  • Multifunctional chiller.
  • Wide range of aggregates including 15 models.
  • Average step of 60 kW.
  • Increased EER.
  • High COP.
  • Increased ESEER
  • Twin-screw compressors.
  • Double refrigeration circuit.
  • Refrigerant charge - R134a.
  • Shell-and-tube heat exchanger.
  • AC axial fans.
  • Double air circuit.
  • Suitable for indoor installation.
Features

WORKING LIMITS IN COOLING MODE:

  • Chilled water outlet temperature: -10÷15°C
  • Ambient temperature: -20÷50°C

 

WORKING LIMITS IN HEATING MODE:

  • Hot water outlet temperature: 20÷63°C
  • Ambient temperature: -10÷20°C

 

ADVANTAGES:

  • IDEA® dynamic defrost monitoring system.
  • Pumping group.
  • Systems of partial heat recovery.
  • Noise-suppressing kit.
  • EC fans with high efficiency.
  • Ease of maintenance.

 

POWER SUPPLY: 400/3/50.

 

COMPONENTS:

  • FRAMEWORK: steel with protective epoxy coating; color: RAL 9002; compressor compartment.
  • COMPRESSORS: twin-screw semi-hermetic compressors with highly effective screw profile and high peripheral speed; integrated discharge check valve; replaceable oil filter cartridge; oil flow switch; oil level indicator; thermal protection of the motor via temperature sensors; phases control relay; anti-vibration rubber supports.
  • EVAPORATOR from model 200 V2 U04 to 280 V2 U06: brazed plate heat exchanger made of stainless steel; polyurethane insulation; water temperature sensors at the air inlet and outlet; antifreeze heater.
  • EVAPORATOR from model 330 V2 U08 to 1070 V2 U14: shell-and-tube evaporator; tubes with a helical rifled internal surface; shell, header, tube sheets, made of carbon steel, copper tubes; polyurethane insulation; water outlet temperature sensor.
  • REFRIGERATING CIRCUIT: reversing valve for refrigerant circuit inversion; electronic expansion valves; sight glass; service valves on suction line and gas discharge; safety valve on the line of low and high pressure; IDEA® dynamic defrost monitoring system; cooling circuit with copper tubes and thermal insulation on the suction line.
  • ELECTRICAL PANEL: main switch with safety lock; magneto-thermal switches or fuses for fans; contactors for compressors; ambient temperature sensor.
  • CONTROL SYSTEM: MP.COM microprocessor control with graphical display; volt-free contact as an element of the general emergency warning system; real clock timer; flash memory; components hour-meter; a password-protected menu; LAN connection.