Heat pumps
Reversible air-to-water units
Reversible unit, air source for outdoor installation 35,8-219 kW
Series
NX-N 0152P - 0812P

Outdoor unit with heat pump for the production of chilled/hot water with hermetic rotary scroll compressors dedicated to the use of R410A, axial fans, plate heat exchanger, condensing coil with copper tubes and aluminum fins and thermostatic or electronic expansion valve, according to the version. The range is composed by units equipped with two compressors in a single-circuit configuration.

Керування:

W3000 Base – W3000SE Compact

The controller in two different versions according to the unit’s type:

W3000 Base: electronic controller complete with keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a menu up to three languages (Italian and English come standard, a further language can be chosen within French, Spanish, German, Russian and Swedish)

W3000SE Compact: electronic controller complete with keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-language menu, with selectable language setting on site. This controller also includes an internal clock.

All the W3000 electronic controllers offer advanced functions and algorithms.

The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting.

The regulation is based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. As alternatives the proportional- or proportional- integral regulations are also available.

The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analysis of the unit operation (available on W3000SE Compact only).

For multiple units’ systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed.

Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks.

Compatibility with the remote keyboard managing up to 10 units. 

The internal real time clock allows to manage a weekly schedule operating on 4-day profiles with 10 hour belts (available on W3000SE Compact only, optional on W3000 Base controller).

The defrost adopts a proprietary self-adaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefit for the overall energy efficiency.

Features

Characteristics

VERSION
K             Key efficiency, compact version
LN-K      Low Noise, Key efficiency and compact version
CA         Class A of efficiency
LN-CA  Low Noise, Class A of efficiency

CONFIGURATIONS

-             Basic function

D         Partial condensing heat recovery function
 

REFRIGERANT GAS R410A

The use of R410A allowed to achive better energy efficiencies with environment full respect (ODP = 0)

ELECTRONIC EXPANSION VALVE

The use of the electronic expansion valve generates considerable benefits, especially in cases of variable demand and different external conditions. It has been introduced into these units as a result of accurate design choices concerning the cooling circuit and the optimisation of operation in various different working conditions. The electronic expansion valve comes standard in the high-efficieny CA version. 

CLASS A EFFICIENCY

The full range is also available with the Class A efficiency rating (in heating). NX-N/CA guaranties within all the noise configurations premium levels of efficiency thanks to the generous sizing of the refrigerant-exchange surface areas and to an accurate control of the fans.

WIDE OPERATING RANGE

Unit´s operation guaranteed with external air temperature down to -10 °C during winter and up to 46 °C during summer.

COMPLIANCE WITH THE STRICTEST EUROPEAN STANDARDS

The main new feature that distinguishes the new NX-N units regards the calculation methods used to define the energy efficiency values. These values are in fact now calculated not only based on the capacity delivered and power consumed by the unit, but also taking into account heat exchanger pressure drop, or the available pressure head if the unit is installed with pumps, as required by European standard EN14511.
In this way, energy efficiency is no longer an index for evaluating the unit alone, but rather extends the assessment by considering the unit within the system, consequently taking into account the energy required to pump the refrigerant or heat carrier fluid used in the system.

TWO SOUND EMISSION LEVELS

The new NX-N appliances have two different sound emission levels. This means the best unit can be identified based on requirements, according to the system where it will be installed and the application.

INTEGRATED HYDRONIC GROUP

The optional built-in hydronic module already contains the main water circuit components; it is available with single or twin in-line, for achieving both low or high head.

Accessory

  • Soft starters
  • Set-up for remote connectivity with ModBus/Echelon protocol cards
  • Remote control keyboard (distance to 200m and to 500m)