Rooftop units
Air-to-air rooftop units, cooling only
Cooling only air cooled Rooftop unit, fully configurable and high efficiency 50,9-422 kW
Series
WSM-T 0162 - 1204

Autonomous cooling only air-to-air Rooftop unit, for the thermo-hygrometric treatment, filtration and air renovation, in medium-large surface and volume ambient, such as supermarkets, shopping or exhibition centres. Hermetic rotary scroll compressors with R410A refrigerant; double refrigerant circuit; aluminum structure and coated galvanized steel base; air treatment section with sandwich panel and EC plug fans. According to the selected version, the unit allows for the management of free cooling, with supply and return fans with motorized dampers for return, expulsion and fresh air. The unit is also available with the thermodynamic Refrigerant Booster heat recovery or air-to air Plate type, to recover the energy from the exhaust air, increasing the units capacity and the global efficiency.

Controls

AIR3000TE
The AIR3000 TE controller offers advanced functions and algorithms. It is made up by two control boards, dedicated to the air side and the refrigerant side respectively. The keypad features functional controls and a complete LCD display that allows for the monitoring and intervention on the unit by means of a multi-level menu with selectable user´s language.

The step proportional capacity adjustment is based on the return temperature; proportional-integral management can also be set. Its functions include the adjustment of the ambient humidity, the thermal or enthalpic (optional) free-cooling and supply temperature limitation. Defrosting is based on a self-adaptive propriety logic with monitoring of several operating and environmental parameters. The management of the ventilation can be realized with constant air flow regulation (optional): as pressure drop varies, the fans change speed so as to
maintain the flow-rate at the designed value for the system, regardless of filter clogging.

The controller allows to integrate and automatically manage different optional thermal resources (hot water coil, electrical heater and gas thermal module), hot gas post-heating (optional) and the fresh air percentage (optional with CO2 sensor or remote signal 4-20 mA).

The presence of the programmable timer allows the user to create an operating profile containing up to 4 typical days and 10 time bands.

The diagnostics comprises a complete alarm management system, including ‘black box’ (via PC) functions and an alarm log list (via display or also a PC) for optimized analysis of the unit performance.

Supervision can be easily developed via proprietary devices or via third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks protocols. 

Compatibility with the remote keyboard managing up to 8 units.

Features

Characteristics

CONFIGURATIONS

AR     Air recirculation function
MF     Mixing and Free cooling function
CE     Function with fans for extraction and expulsion and Free cooling
HR-B   Heat Recovery Refrigerant Booster function: air extractor fan(s), free cooling function and heat recovery from exhaust air flow thanks to
Refrigerant Booster coil
HR-P   Heat Recovery Plate function: air extractor fan(s), free cooling function and heat recovery from exhaust air flow thanks to Plate heat
Exchanger.

FLEXIBILITY

Climaveneta’s units offer the opportunity to choose different supply and return airflows directions.

HIGH RELIABILITY

The wide working range, the double refrigerant circuit and the accurate design of the components ensure optimum performance and comfort, with a continuous and constant operation also during heavy thermoigrometric conditions.

VERSATILITY

Different possibilities for the air treatment chambers; from total recirculation only to mixing with fresh air and extraction from the ambient with heat recovery. Each different configuration can be further customized thanks to a wide range of accessories.

REFRIGERANT BOOSTER

Cutting-edge Refrigerant booster heat recovery system that allows for the complete and precise recovery of the energy from the exhaust air, without any waste due to the mixing with external air. The performance of the cooling circuit is maximized, increasing by 15% the cooling capacity and the compressor working at the same condition.

INSTALLATION AND MAINTENANCE

Simplified operations, reduced costs and maintenance directly on site thanks to: the strong and perfectly insulated structure, easy access to internal sections, plug & play approach and automatic setting of the air flow (optional).

Accessory

  • Ambient humidity control: hot gas post heating coil and humidifer.
  • Ambient air quality control: CO2 sensor or 4-20 mA remote signal.
  • Integration or substitution heating resources: hot water heating coil, electrical heaters, gas heating module
  • High efficiency filters: electronic or rigid pocket F7
  • Enthalpy free-cooling
  • Remote control keyboard (distance to 200m and to 500m)
  • Set-up for remote connectivity with ModBus/Echelon protocol cards